This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use,
see our Privacy Policy.

Open House • Learn how you can grow your career with us! • May 15 • 3:00–6:00 p.m. • Merrimack, NH
Tripp Lite ATS Monitored PDU, 230V 3.7kW 1-ph, 1U, (2) IEC309 16A Blue Inputs, IEC309 16A Blue Outlet
-
Temporarily Out-of-Stock
- Call for next available delivery
Add to Cart
Messages
Loading
-
:
Quick View
Getting Details
The PDUMNH16HVAT 3.7kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.
Dual 10-foot input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1-5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.
Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1%). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).
Dual 10-foot input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1-5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.
Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1%). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).
-
17.36 lbs
-
Features
Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
IEC309 16A Blue(2P+E) inputs with 10 ft. cords connect to separate primary and secondary single-phase power sources
Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS
Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input (sold separately)
Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
1-5ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor
Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP
Real-time load/current data with billing-grade accuracy(+/- 1 percent)
Tiered access privileges allow both an administrator and guest to log in
Optional ENVIROSENSE module (sold separately) monitors temperature and humidity
Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP
10/100 Mbps auto-sensing for communication with 10/100 Base-T networks
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD: Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor
Front Panel LEDs: Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status
Switches: ENTER and MODE switches toggle the digital display to display all reported information -
# Ports: 1Connector: Power IEC 309 EN 60309 16AConnector: Power IEC 60309 16A
-
PDU, rack-mounting brackets, documentation
-
Color: BlackForm Factor: 1U RackmountForm Factor: Rack-mountableWarranty Period: 2 yearsWeight Taxonomy: 17.37lbs
-
1.7"h x 16.9"w x 14"d
-
Output Receptacles: (1) IEC309 16A BLUE (2P+E)
PDU Plug Type: IEC-309 16A BLUE (2P+E)
Input Cord Length: 10ft
Input Cord Details: Set of two input cables for separate PRIMARY and SECONDARY input connections -
Power Provided: 3.8kWVoltage Provided: 240VVoltage Provided: AC 200/208/220/230/240V
-
Specifications
PDU Type: Monitored; Auto-Transfer Switch
OUTPUT
Output Capacity Details: 3.8kW (240V); 3.7kW (230V); 3.5kW (220V); 3.3kW (208V); 3.2kW (200V); 16A maximum
Frequency Compatibility: 50/60Hz
Output Nominal Voltage: 240, 230, 220, 208, 200V
Overload Protection: n/a
INPUT
PDU Input Voltage: 200; 208; 220; 230; 240V
Recommended Electrical Service: 16A, 230V
Maximum Input: 16A
Input Phase: Single-Phase -
Remote Management Protocol: HTTPRemote Management Protocol: HTTPSRemote Management Protocol: SNMP 1Remote Management Protocol: SNMP 2Remote Management Protocol: SNMP 3Remote Management Protocol: SSHRemote Management Protocol: Telnet
-
This product is subject to our return policy. Please see our complete return policy for details.
-
17.4 lbs
-
Compliant Standards: FCC Class A certifiedCompliant Standards: IEC 60950-1Compliant Standards: RoHS
-
39121017
Description | Availability | Unit Price | ||
---|---|---|---|---|
View All Warranties |
Batch Add Products by Item #
13