This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use,
see our Privacy Policy.

Tripp Lite Power Distribution Unit (PDU) Finder
Tripp Lite Metered PDU 5.8kW 208 240V Single-Phase L6-30P Input 10ft Cord (8) C19 (40) C13 0U x 70"h, TAA
-
Limited Quantity Available
- Call for next available delivery
Add to Cart
Messages
Loading
-
:
Quick View
Getting Details
The 70-inch (178-centimeter) PDUMV30HV2 30A 208/240V 5.8kW Single-Phase Metered Power Distribution Unit features (48) outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers.
Outlets are arranged in two separate load banks, each with (24) outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank's real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification.
An ideal PDU for server rooms, network closets and data centers, the PDUMV30HV2's all-metal housing comes ready to mount vertically in your rack using the pre-installed 9mm buttons or the included hardware. The NEMA L6-30P input plug with 10-foot (3-meter) cord connects to your facility's compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components' plugs to ensure they remain connected and continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground.
Outlets are arranged in two separate load banks, each with (24) outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank's real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification.
An ideal PDU for server rooms, network closets and data centers, the PDUMV30HV2's all-metal housing comes ready to mount vertically in your rack using the pre-installed 9mm buttons or the included hardware. The NEMA L6-30P input plug with 10-foot (3-meter) cord connects to your facility's compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components' plugs to ensure they remain connected and continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground.
-
12.35 lbs
-
Features
Dual digital ammeters report real-time output current in amps
Visual monitoring of PDU load level prevents overloading as more equipment is connected
30A 208/240V 5.8kW metered PDU(agency derated to 24A continuous)
Dual load banks with separate 20A circuit breakers and digital ammeters
(48) outlets - (24) per bank (4 C19 and 20 C13) - distribute single-phase power to connected equipment
Special guards prevent breakers from accidentally tripping
Each bank is color-coded and labeled for convenient identification
NEMA L6-30P input plug with 10 ft.(3 m) cord for easy connection to main power source, generator or protected UPS
Included plug-lock inserts ensure components remain connected and powered
Included ground screw for equipment requiring chassis ground
Ready for immediate toolless 0U installation using preinstalled 9 mm mounting buttons(spare 2.9 mm and 4.6 mm buttons included)
Nut-and-bolt vertical installation possible with included mounting hardware
Use included PDUMVROTATEBRKT mounting accessory for installation with outlets facing rear
Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases -
Connector: Power NEMA L6-30
-
PDU, plug-lock inserts, spare buttons, ground screw, mounting hardware, documentation
-
Color: BlackForm Factor: Rack-mountableWarranty Period: 2 yearsWeight Taxonomy: 12.35lbs
-
70"h x 2.2"w x 2.5"d
-
Output Receptacles: (40) C13, (8) C19
PDU Plug Type: NEMA L6-30P
Input Cord Length: 10ft -
Power Provided: 5.8kWVoltage Provided: AC 200-240V
-
Output
Output Capacity Details: 5kW (208V input), 5.8kW (240V input), 4.8kW (200V input); 30A max. output (agency de-rated to 24A), 20A max. per breakered load bank, 16A max per C19 outlet, 12A max per C13 outlet
Frequency Compatibility: 50/60Hz
Output Nominal Voltage: 200-240V nominal, single phase
Overload Protection: Set of (2) 20A breakers protect output Bank 1 and Bank 2
Input
PDU Input Voltage: 200V, 208V, 240V
Maximum Input Current: 30A
Maximum Input Amps Details: Agency de-rated to 24A continuous -
This product is subject to our return policy. Please see our complete return policy for details.
-
12.35 lbs
-
Compliant Standards: TAACompliant Standards: Yes
-